Application of the steepest slope model reveals different perfusion territories within the mouse placenta

Standard

Application of the steepest slope model reveals different perfusion territories within the mouse placenta. / Remus, C C; Sedlacik, J; Wedegärtner, Ulrike; Arck, Petra; Hecher, K; Adam, G; Forkert, N D.

in: PLACENTA, Jahrgang 34, Nr. 10, 01.10.2013, S. 899-906.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{b12424ba2072403da94e0453c32b12ed,
title = "Application of the steepest slope model reveals different perfusion territories within the mouse placenta",
abstract = "OBJECTIVES: The steepest slope model is a numerically robust and fast method for perfusion quantification. The purpose of this study was to evaluate if the steepest slope model can be used for quantifying placental perfusion in mice based on dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) datasets.MATERIAL AND METHODS: T1-weighted DCE MRI was performed in 5 pregnant BALB/c mice on gestation day (gd) 14.5 and in 5 mice on gd 16.5 using a 7T small animal MRI scanner. The placentas were manually delineated in the DCE datasets and the arterial input function (AIF) was selected from the kidney hilus. Placental perfusion was determined on a voxel-by-voxel basis using the steepest slope model. Perfusion was averaged over the entire placenta as well as separately calculated for the high-flow compartment within the central labyrinth zone and for the remaining low-flow placenta tissue. The AIF selection was independently performed by two observers for assessment of inter-observer differences.RESULTS: Mean perfusion on gd 14.5 was 135 ml/min/100 ml (standard deviation SD: 29 ml/min/100 ml placenta) and 112 ml/min/100 ml on gd 16.5 for the whole placenta (SD: 32 ml/min/100 ml). Perfusion in the high flow compartment in the central labyrinth was significantly higher (p ≤ 0.002) than in the low-flow compartment including the remaining placenta tissue: 184 ml/min/100 ml (SD: 39 ml/min/100 ml) vs. 119 ml/min/100 ml (SD 28 ml/min/100 ml) on gd 14.5 and 158 ml/min/100 ml (SD: 58 ml/min/100 ml) vs. 114 ml/min/100 ml (SD: 52 ml/min/100 ml of placenta) on gd 16.5. The mean relative inter-rater observer difference was 6%.CONCLUSION: The steepest slope model is a computationally simple method, which allows perfusion quantification in the mouse placenta. Furthermore, the results of this work indicate that the different placental compartments should be analyzed separately to prevent biased results due to averaging.",
keywords = "Animals, Contrast Media, Female, Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging, Mice, Mice, Inbred BALB C, Placenta, Placental Circulation, Pregnancy",
author = "Remus, {C C} and J Sedlacik and Ulrike Wedeg{\"a}rtner and Petra Arck and K Hecher and G Adam and Forkert, {N D}",
note = "Copyright {\textcopyright} 2013 Elsevier Ltd. All rights reserved.",
year = "2013",
month = oct,
day = "1",
doi = "10.1016/j.placenta.2013.06.304",
language = "English",
volume = "34",
pages = "899--906",
journal = "PLACENTA",
issn = "0143-4004",
publisher = "W.B. Saunders Ltd",
number = "10",

}

RIS

TY - JOUR

T1 - Application of the steepest slope model reveals different perfusion territories within the mouse placenta

AU - Remus, C C

AU - Sedlacik, J

AU - Wedegärtner, Ulrike

AU - Arck, Petra

AU - Hecher, K

AU - Adam, G

AU - Forkert, N D

N1 - Copyright © 2013 Elsevier Ltd. All rights reserved.

PY - 2013/10/1

Y1 - 2013/10/1

N2 - OBJECTIVES: The steepest slope model is a numerically robust and fast method for perfusion quantification. The purpose of this study was to evaluate if the steepest slope model can be used for quantifying placental perfusion in mice based on dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) datasets.MATERIAL AND METHODS: T1-weighted DCE MRI was performed in 5 pregnant BALB/c mice on gestation day (gd) 14.5 and in 5 mice on gd 16.5 using a 7T small animal MRI scanner. The placentas were manually delineated in the DCE datasets and the arterial input function (AIF) was selected from the kidney hilus. Placental perfusion was determined on a voxel-by-voxel basis using the steepest slope model. Perfusion was averaged over the entire placenta as well as separately calculated for the high-flow compartment within the central labyrinth zone and for the remaining low-flow placenta tissue. The AIF selection was independently performed by two observers for assessment of inter-observer differences.RESULTS: Mean perfusion on gd 14.5 was 135 ml/min/100 ml (standard deviation SD: 29 ml/min/100 ml placenta) and 112 ml/min/100 ml on gd 16.5 for the whole placenta (SD: 32 ml/min/100 ml). Perfusion in the high flow compartment in the central labyrinth was significantly higher (p ≤ 0.002) than in the low-flow compartment including the remaining placenta tissue: 184 ml/min/100 ml (SD: 39 ml/min/100 ml) vs. 119 ml/min/100 ml (SD 28 ml/min/100 ml) on gd 14.5 and 158 ml/min/100 ml (SD: 58 ml/min/100 ml) vs. 114 ml/min/100 ml (SD: 52 ml/min/100 ml of placenta) on gd 16.5. The mean relative inter-rater observer difference was 6%.CONCLUSION: The steepest slope model is a computationally simple method, which allows perfusion quantification in the mouse placenta. Furthermore, the results of this work indicate that the different placental compartments should be analyzed separately to prevent biased results due to averaging.

AB - OBJECTIVES: The steepest slope model is a numerically robust and fast method for perfusion quantification. The purpose of this study was to evaluate if the steepest slope model can be used for quantifying placental perfusion in mice based on dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) datasets.MATERIAL AND METHODS: T1-weighted DCE MRI was performed in 5 pregnant BALB/c mice on gestation day (gd) 14.5 and in 5 mice on gd 16.5 using a 7T small animal MRI scanner. The placentas were manually delineated in the DCE datasets and the arterial input function (AIF) was selected from the kidney hilus. Placental perfusion was determined on a voxel-by-voxel basis using the steepest slope model. Perfusion was averaged over the entire placenta as well as separately calculated for the high-flow compartment within the central labyrinth zone and for the remaining low-flow placenta tissue. The AIF selection was independently performed by two observers for assessment of inter-observer differences.RESULTS: Mean perfusion on gd 14.5 was 135 ml/min/100 ml (standard deviation SD: 29 ml/min/100 ml placenta) and 112 ml/min/100 ml on gd 16.5 for the whole placenta (SD: 32 ml/min/100 ml). Perfusion in the high flow compartment in the central labyrinth was significantly higher (p ≤ 0.002) than in the low-flow compartment including the remaining placenta tissue: 184 ml/min/100 ml (SD: 39 ml/min/100 ml) vs. 119 ml/min/100 ml (SD 28 ml/min/100 ml) on gd 14.5 and 158 ml/min/100 ml (SD: 58 ml/min/100 ml) vs. 114 ml/min/100 ml (SD: 52 ml/min/100 ml of placenta) on gd 16.5. The mean relative inter-rater observer difference was 6%.CONCLUSION: The steepest slope model is a computationally simple method, which allows perfusion quantification in the mouse placenta. Furthermore, the results of this work indicate that the different placental compartments should be analyzed separately to prevent biased results due to averaging.

KW - Animals

KW - Contrast Media

KW - Female

KW - Image Interpretation, Computer-Assisted

KW - Magnetic Resonance Imaging

KW - Mice

KW - Mice, Inbred BALB C

KW - Placenta

KW - Placental Circulation

KW - Pregnancy

U2 - 10.1016/j.placenta.2013.06.304

DO - 10.1016/j.placenta.2013.06.304

M3 - SCORING: Journal article

C2 - 23849931

VL - 34

SP - 899

EP - 906

JO - PLACENTA

JF - PLACENTA

SN - 0143-4004

IS - 10

ER -