An Investigation of Transient Severe Motion Related to Gadoxetic Acid-enhanced MR Imaging

Standard

An Investigation of Transient Severe Motion Related to Gadoxetic Acid-enhanced MR Imaging. / Motosugi, Utaroh; Bannas, Peter; Bookwalter, Candice A; Sano, Katsuhiro; Reeder, Scott B.

in: RADIOLOGY, Jahrgang 279, Nr. 1, 01.04.2016, S. 93-102.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{6ac93f8cee584052aa9fa66f259a72ce,
title = "An Investigation of Transient Severe Motion Related to Gadoxetic Acid-enhanced MR Imaging",
abstract = "Purpose To investigate the cause of imaging artifacts observed during gadoxetic acid-enhanced arterial phase imaging of the liver. Materials and Methods This HIPAA-compliant study was approved by the institutional review board. Data were collected prospectively at two sites (site A, United States; site B, Japan) from patients undergoing contrast material-enhanced MR imaging with gadoxetic acid (site A, n = 154, dose = 0.05 mmol/kg; site B, n = 130, 0.025 mmol/kg) or gadobenate dimeglumine (only site A, n = 1666) from January 2014 to September 2014 at site A and from November 2014 to January 2015 at site B. Detailed comparisons between the two agents were made in the patients with dynamic liver acquisitions (n = 372) and age-, sex-, and baseline oxygen saturation (Spo2)-matched pairs (n = 130) at site A. Acquired data included self-reported dyspnea after contrast agent injection, Spo2, and breath-hold fidelity monitored with respiratory bellows. Results Self-reported dyspnea was more frequent with gadoxetic acid than with gadobenate dimeglumine (site A, 6.5% [10 of 154] vs 0.1% [two of 1666], P < .001; site B, 1.5% [two of 130]). In the matched-pair comparison, gadoxetic acid, as compared with gadobenate dimeglumine, had higher breath-hold failure rates (site A, 34.6% [45 of 130] vs 11.7% [15 of 130], P < .0001; site B, 16.2% [21 of 130]) and more severe artifacts during arterial phase imaging (site A, 7.7% [10 of 130] vs 0% [none of 130], P < .001; site B, 2.3% [three of 130]). Severe imaging artifacts in patients who received gadoxetic acid were significantly associated with male sex (P = .023), body mass index (P = .021), and breath-hold failure (P < .001) but not with dyspnea or Spo2 decrease. Conclusion Severe motion-related artifacts in the arterial phase of gadoxetic acid-enhanced liver MR imaging are associated with breath-hold failure but not with subjective feelings of dyspnea or a substantial decrease in blood Spo2. Subjective feelings of dyspnea are not necessarily associated with imaging artifacts. The phenomenon, albeit at a lower rate, was confirmed at a second site in Japan. ({\textcopyright}) RSNA, 2015 Online supplemental material is available for this article.",
author = "Utaroh Motosugi and Peter Bannas and Bookwalter, {Candice A} and Katsuhiro Sano and Reeder, {Scott B}",
year = "2016",
month = apr,
day = "1",
doi = "10.1148/radiol.2015150642",
language = "English",
volume = "279",
pages = "93--102",
journal = "RADIOLOGY",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "1",

}

RIS

TY - JOUR

T1 - An Investigation of Transient Severe Motion Related to Gadoxetic Acid-enhanced MR Imaging

AU - Motosugi, Utaroh

AU - Bannas, Peter

AU - Bookwalter, Candice A

AU - Sano, Katsuhiro

AU - Reeder, Scott B

PY - 2016/4/1

Y1 - 2016/4/1

N2 - Purpose To investigate the cause of imaging artifacts observed during gadoxetic acid-enhanced arterial phase imaging of the liver. Materials and Methods This HIPAA-compliant study was approved by the institutional review board. Data were collected prospectively at two sites (site A, United States; site B, Japan) from patients undergoing contrast material-enhanced MR imaging with gadoxetic acid (site A, n = 154, dose = 0.05 mmol/kg; site B, n = 130, 0.025 mmol/kg) or gadobenate dimeglumine (only site A, n = 1666) from January 2014 to September 2014 at site A and from November 2014 to January 2015 at site B. Detailed comparisons between the two agents were made in the patients with dynamic liver acquisitions (n = 372) and age-, sex-, and baseline oxygen saturation (Spo2)-matched pairs (n = 130) at site A. Acquired data included self-reported dyspnea after contrast agent injection, Spo2, and breath-hold fidelity monitored with respiratory bellows. Results Self-reported dyspnea was more frequent with gadoxetic acid than with gadobenate dimeglumine (site A, 6.5% [10 of 154] vs 0.1% [two of 1666], P < .001; site B, 1.5% [two of 130]). In the matched-pair comparison, gadoxetic acid, as compared with gadobenate dimeglumine, had higher breath-hold failure rates (site A, 34.6% [45 of 130] vs 11.7% [15 of 130], P < .0001; site B, 16.2% [21 of 130]) and more severe artifacts during arterial phase imaging (site A, 7.7% [10 of 130] vs 0% [none of 130], P < .001; site B, 2.3% [three of 130]). Severe imaging artifacts in patients who received gadoxetic acid were significantly associated with male sex (P = .023), body mass index (P = .021), and breath-hold failure (P < .001) but not with dyspnea or Spo2 decrease. Conclusion Severe motion-related artifacts in the arterial phase of gadoxetic acid-enhanced liver MR imaging are associated with breath-hold failure but not with subjective feelings of dyspnea or a substantial decrease in blood Spo2. Subjective feelings of dyspnea are not necessarily associated with imaging artifacts. The phenomenon, albeit at a lower rate, was confirmed at a second site in Japan. (©) RSNA, 2015 Online supplemental material is available for this article.

AB - Purpose To investigate the cause of imaging artifacts observed during gadoxetic acid-enhanced arterial phase imaging of the liver. Materials and Methods This HIPAA-compliant study was approved by the institutional review board. Data were collected prospectively at two sites (site A, United States; site B, Japan) from patients undergoing contrast material-enhanced MR imaging with gadoxetic acid (site A, n = 154, dose = 0.05 mmol/kg; site B, n = 130, 0.025 mmol/kg) or gadobenate dimeglumine (only site A, n = 1666) from January 2014 to September 2014 at site A and from November 2014 to January 2015 at site B. Detailed comparisons between the two agents were made in the patients with dynamic liver acquisitions (n = 372) and age-, sex-, and baseline oxygen saturation (Spo2)-matched pairs (n = 130) at site A. Acquired data included self-reported dyspnea after contrast agent injection, Spo2, and breath-hold fidelity monitored with respiratory bellows. Results Self-reported dyspnea was more frequent with gadoxetic acid than with gadobenate dimeglumine (site A, 6.5% [10 of 154] vs 0.1% [two of 1666], P < .001; site B, 1.5% [two of 130]). In the matched-pair comparison, gadoxetic acid, as compared with gadobenate dimeglumine, had higher breath-hold failure rates (site A, 34.6% [45 of 130] vs 11.7% [15 of 130], P < .0001; site B, 16.2% [21 of 130]) and more severe artifacts during arterial phase imaging (site A, 7.7% [10 of 130] vs 0% [none of 130], P < .001; site B, 2.3% [three of 130]). Severe imaging artifacts in patients who received gadoxetic acid were significantly associated with male sex (P = .023), body mass index (P = .021), and breath-hold failure (P < .001) but not with dyspnea or Spo2 decrease. Conclusion Severe motion-related artifacts in the arterial phase of gadoxetic acid-enhanced liver MR imaging are associated with breath-hold failure but not with subjective feelings of dyspnea or a substantial decrease in blood Spo2. Subjective feelings of dyspnea are not necessarily associated with imaging artifacts. The phenomenon, albeit at a lower rate, was confirmed at a second site in Japan. (©) RSNA, 2015 Online supplemental material is available for this article.

U2 - 10.1148/radiol.2015150642

DO - 10.1148/radiol.2015150642

M3 - SCORING: Journal article

C2 - 26473642

VL - 279

SP - 93

EP - 102

JO - RADIOLOGY

JF - RADIOLOGY

SN - 0033-8419

IS - 1

ER -