Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws

Standard

Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws. / Hansen-Algenstaedt, Nils; Chiu, Chee Kidd; Chan, Chris Yin Wei; Lee, Chee Kean; Schäfer, Christian; Kwan, Mun Keong.

in: SPINE, Jahrgang 40, Nr. 17, 01.09.2015, S. E954-63.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Hansen-Algenstaedt, N., Chiu, C. K., Chan, C. Y. W., Lee, C. K., Schäfer, C., & Kwan, M. K. (2015). Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws. SPINE, 40(17), E954-63. https://doi.org/10.1097/BRS.0000000000000958

Vancouver

Bibtex

@article{ea01b043c4d840f4bb6c82b35a91b60f,
title = "Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws",
abstract = "STUDY DESIGN: Retrospective study.OBJECTIVE: To investigate the accuracy and safety of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracic and lumbosacral spine.SUMMARY OF BACKGROUND DATA: Several studies had examined the accuracy and safety of percutaneous pedicle screws but provided large variations in their results with small number of patients or few number of pedicle screws evaluated.METHODS: Computerized tomography of patients who had surgery with fluoroscopic guided percutaneous pedicle screws were chosen from 2 centers: (1) European patients from University Medical Center Hamburg-Eppendorf, Germany and (2) Asian patients from University Malaya Medical Centre, Malaysia. Screw perforations were classified into Grade 0, Grade 1 (<2 mm), Grade 2 (2-4 mm), and Grade 3 (>4 mm).RESULTS: In total, 2000 percutaneous pedicle screws from 273 patients were analyzed: 1290 screws from 183 European patients and 710 screws from 90 Asian patients. The mean age was 59.1 ± 15.6. There were 140 male patients and 133 female patients. The total perforation rate was 9.4% with 151 (7.5%) Grade 1, 31 (1.6%) Grade 2, and 5 (0.3%) Grade 3 perforations. The total perforation rates among Europeans were 9.4% and among Asians were 9.3%. There was no difference between the 2 groups (P > 0.05). There were 3 distinct peaks in perforation rates (trimodal distribution) at T1, midthoracic region (T4-T7), and lumbosacral junction (L5 and S1). The highest perforation rates were at T1 (33.3%), S1 (19.4%), and T4 (18.6%).CONCLUSION: Implantation of percutaneous pedicle screws insertion using fluoroscopic guidance is safe and has the accuracy comparable to open techniques of pedicle screws insertion.LEVEL OF EVIDENCE: 4.",
author = "Nils Hansen-Algenstaedt and Chiu, {Chee Kidd} and Chan, {Chris Yin Wei} and Lee, {Chee Kean} and Christian Sch{\"a}fer and Kwan, {Mun Keong}",
year = "2015",
month = sep,
day = "1",
doi = "10.1097/BRS.0000000000000958",
language = "English",
volume = "40",
pages = "E954--63",
journal = "SPINE",
issn = "0362-2436",
publisher = "Lippincott Williams and Wilkins",
number = "17",

}

RIS

TY - JOUR

T1 - Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws

AU - Hansen-Algenstaedt, Nils

AU - Chiu, Chee Kidd

AU - Chan, Chris Yin Wei

AU - Lee, Chee Kean

AU - Schäfer, Christian

AU - Kwan, Mun Keong

PY - 2015/9/1

Y1 - 2015/9/1

N2 - STUDY DESIGN: Retrospective study.OBJECTIVE: To investigate the accuracy and safety of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracic and lumbosacral spine.SUMMARY OF BACKGROUND DATA: Several studies had examined the accuracy and safety of percutaneous pedicle screws but provided large variations in their results with small number of patients or few number of pedicle screws evaluated.METHODS: Computerized tomography of patients who had surgery with fluoroscopic guided percutaneous pedicle screws were chosen from 2 centers: (1) European patients from University Medical Center Hamburg-Eppendorf, Germany and (2) Asian patients from University Malaya Medical Centre, Malaysia. Screw perforations were classified into Grade 0, Grade 1 (<2 mm), Grade 2 (2-4 mm), and Grade 3 (>4 mm).RESULTS: In total, 2000 percutaneous pedicle screws from 273 patients were analyzed: 1290 screws from 183 European patients and 710 screws from 90 Asian patients. The mean age was 59.1 ± 15.6. There were 140 male patients and 133 female patients. The total perforation rate was 9.4% with 151 (7.5%) Grade 1, 31 (1.6%) Grade 2, and 5 (0.3%) Grade 3 perforations. The total perforation rates among Europeans were 9.4% and among Asians were 9.3%. There was no difference between the 2 groups (P > 0.05). There were 3 distinct peaks in perforation rates (trimodal distribution) at T1, midthoracic region (T4-T7), and lumbosacral junction (L5 and S1). The highest perforation rates were at T1 (33.3%), S1 (19.4%), and T4 (18.6%).CONCLUSION: Implantation of percutaneous pedicle screws insertion using fluoroscopic guidance is safe and has the accuracy comparable to open techniques of pedicle screws insertion.LEVEL OF EVIDENCE: 4.

AB - STUDY DESIGN: Retrospective study.OBJECTIVE: To investigate the accuracy and safety of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracic and lumbosacral spine.SUMMARY OF BACKGROUND DATA: Several studies had examined the accuracy and safety of percutaneous pedicle screws but provided large variations in their results with small number of patients or few number of pedicle screws evaluated.METHODS: Computerized tomography of patients who had surgery with fluoroscopic guided percutaneous pedicle screws were chosen from 2 centers: (1) European patients from University Medical Center Hamburg-Eppendorf, Germany and (2) Asian patients from University Malaya Medical Centre, Malaysia. Screw perforations were classified into Grade 0, Grade 1 (<2 mm), Grade 2 (2-4 mm), and Grade 3 (>4 mm).RESULTS: In total, 2000 percutaneous pedicle screws from 273 patients were analyzed: 1290 screws from 183 European patients and 710 screws from 90 Asian patients. The mean age was 59.1 ± 15.6. There were 140 male patients and 133 female patients. The total perforation rate was 9.4% with 151 (7.5%) Grade 1, 31 (1.6%) Grade 2, and 5 (0.3%) Grade 3 perforations. The total perforation rates among Europeans were 9.4% and among Asians were 9.3%. There was no difference between the 2 groups (P > 0.05). There were 3 distinct peaks in perforation rates (trimodal distribution) at T1, midthoracic region (T4-T7), and lumbosacral junction (L5 and S1). The highest perforation rates were at T1 (33.3%), S1 (19.4%), and T4 (18.6%).CONCLUSION: Implantation of percutaneous pedicle screws insertion using fluoroscopic guidance is safe and has the accuracy comparable to open techniques of pedicle screws insertion.LEVEL OF EVIDENCE: 4.

U2 - 10.1097/BRS.0000000000000958

DO - 10.1097/BRS.0000000000000958

M3 - SCORING: Journal article

C2 - 25929207

VL - 40

SP - E954-63

JO - SPINE

JF - SPINE

SN - 0362-2436

IS - 17

ER -