A modified transfemoral approach using modular cementless revision stems.
Standard
A modified transfemoral approach using modular cementless revision stems. / Fink, Bernd; Grossmann, Alexandra; Schubring, Svenja; Schulz, Martin S; Fuerst, Martin.
in: CLIN ORTHOP RELAT R, Jahrgang 462, 2007, S. 105-114.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - A modified transfemoral approach using modular cementless revision stems.
AU - Fink, Bernd
AU - Grossmann, Alexandra
AU - Schubring, Svenja
AU - Schulz, Martin S
AU - Fuerst, Martin
PY - 2007
Y1 - 2007
N2 - The transfemoral approach in its traditional form, using a nonmodular Wagner self-locking revision stem, has the disadvantages of a less predictable union rate of the bony flap and a high rate of stem subsidence. To investigate whether this situation can be improved by using a modified transfemoral approach and modular curved cementless revision stems, we prospectively analyzed 68 hip revisions and followed them clinically and radiographically for a minimum of 24 months (mean +/- standard deviation, 32.4 +/- 11.2 months). One year after the operation, the osteotomy showed bony consolidation in all but one case (98.5%). We noted subsidence in six cases (8.8%) and two of these stems became loose. In all of these cases, the circular fixation zone of the stem in the isthmus of the femur was less than 3 cm. The Harris hip score improved continuously from 41.4 +/- 14.5 points preoperatively to 85.9 +/- 14.6 points 24 months postoperatively. The modified transfemoral approach in combination with a curved, modular revision stem showed reproducibly good results concerning union of the bony flap and subsidence of the stem if the fixation zone was not less than 3 cm.
AB - The transfemoral approach in its traditional form, using a nonmodular Wagner self-locking revision stem, has the disadvantages of a less predictable union rate of the bony flap and a high rate of stem subsidence. To investigate whether this situation can be improved by using a modified transfemoral approach and modular curved cementless revision stems, we prospectively analyzed 68 hip revisions and followed them clinically and radiographically for a minimum of 24 months (mean +/- standard deviation, 32.4 +/- 11.2 months). One year after the operation, the osteotomy showed bony consolidation in all but one case (98.5%). We noted subsidence in six cases (8.8%) and two of these stems became loose. In all of these cases, the circular fixation zone of the stem in the isthmus of the femur was less than 3 cm. The Harris hip score improved continuously from 41.4 +/- 14.5 points preoperatively to 85.9 +/- 14.6 points 24 months postoperatively. The modified transfemoral approach in combination with a curved, modular revision stem showed reproducibly good results concerning union of the bony flap and subsidence of the stem if the fixation zone was not less than 3 cm.
M3 - SCORING: Zeitschriftenaufsatz
VL - 462
SP - 105
EP - 114
JO - CLIN ORTHOP RELAT R
JF - CLIN ORTHOP RELAT R
SN - 0009-921X
ER -