4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization.

Standard

4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization. / Bock, Jelena; Frydrychowicz, Alex; Stalder, Aurélien F; Bley, Thorsten; Burkhardt, Hans; Hennig, Jürgen; Markl, Michael.

in: MAGN RESON MED, Jahrgang 63, Nr. 2, 2, 2010, S. 330-338.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bock J, Frydrychowicz A, Stalder AF, Bley T, Burkhardt H, Hennig J et al. 4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization. MAGN RESON MED. 2010;63(2):330-338. 2.

Bibtex

@article{917041c4c5754568a54f3df1d8c79426,
title = "4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization.",
abstract = "Time-resolved phase contrast (PC) MRI with velocity encoding in three directions (flow-sensitive four-dimensional MRI) can be employed to assess three-dimensional blood flow in the entire aortic lumen within a single measurement. These data can be used not only for the visualization of blood flow but also to derive additional information on vascular geometry with three-dimensional PC MR angiography (MRA). As PC-MRA is sensitive to available signal-to-noise ratio, standard and novel blood pool contrast agents may help to enhance PC-MRA image quality. In a group of 30 healthy volunteers, the influence of different contrast agents on vascular signal-to-noise ratio, PC-MRA quality, and subsequent three-dimensional stream-line visualization in the thoracic aorta was determined. Flow-sensitive four-dimensional MRI data acquired with contrast agent provided significantly improved signal-to-noise ratio in magnitude data and noise reduction in velocity data compared to measurements without contrast media. The agreement of three-dimensional PC-MRA with reference standard contrast-enhanced MRA was good for both contrast agents, with improved PC-MRA performance for blood pool contrast agent, particularly for the smaller supra-aortic branches. For three-dimensional flow visualization, a trend toward improved results for the data with contrast agent was observed.",
author = "Jelena Bock and Alex Frydrychowicz and Stalder, {Aur{\'e}lien F} and Thorsten Bley and Hans Burkhardt and J{\"u}rgen Hennig and Michael Markl",
year = "2010",
language = "Deutsch",
volume = "63",
pages = "330--338",
journal = "MAGN RESON MED",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

RIS

TY - JOUR

T1 - 4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization.

AU - Bock, Jelena

AU - Frydrychowicz, Alex

AU - Stalder, Aurélien F

AU - Bley, Thorsten

AU - Burkhardt, Hans

AU - Hennig, Jürgen

AU - Markl, Michael

PY - 2010

Y1 - 2010

N2 - Time-resolved phase contrast (PC) MRI with velocity encoding in three directions (flow-sensitive four-dimensional MRI) can be employed to assess three-dimensional blood flow in the entire aortic lumen within a single measurement. These data can be used not only for the visualization of blood flow but also to derive additional information on vascular geometry with three-dimensional PC MR angiography (MRA). As PC-MRA is sensitive to available signal-to-noise ratio, standard and novel blood pool contrast agents may help to enhance PC-MRA image quality. In a group of 30 healthy volunteers, the influence of different contrast agents on vascular signal-to-noise ratio, PC-MRA quality, and subsequent three-dimensional stream-line visualization in the thoracic aorta was determined. Flow-sensitive four-dimensional MRI data acquired with contrast agent provided significantly improved signal-to-noise ratio in magnitude data and noise reduction in velocity data compared to measurements without contrast media. The agreement of three-dimensional PC-MRA with reference standard contrast-enhanced MRA was good for both contrast agents, with improved PC-MRA performance for blood pool contrast agent, particularly for the smaller supra-aortic branches. For three-dimensional flow visualization, a trend toward improved results for the data with contrast agent was observed.

AB - Time-resolved phase contrast (PC) MRI with velocity encoding in three directions (flow-sensitive four-dimensional MRI) can be employed to assess three-dimensional blood flow in the entire aortic lumen within a single measurement. These data can be used not only for the visualization of blood flow but also to derive additional information on vascular geometry with three-dimensional PC MR angiography (MRA). As PC-MRA is sensitive to available signal-to-noise ratio, standard and novel blood pool contrast agents may help to enhance PC-MRA image quality. In a group of 30 healthy volunteers, the influence of different contrast agents on vascular signal-to-noise ratio, PC-MRA quality, and subsequent three-dimensional stream-line visualization in the thoracic aorta was determined. Flow-sensitive four-dimensional MRI data acquired with contrast agent provided significantly improved signal-to-noise ratio in magnitude data and noise reduction in velocity data compared to measurements without contrast media. The agreement of three-dimensional PC-MRA with reference standard contrast-enhanced MRA was good for both contrast agents, with improved PC-MRA performance for blood pool contrast agent, particularly for the smaller supra-aortic branches. For three-dimensional flow visualization, a trend toward improved results for the data with contrast agent was observed.

M3 - SCORING: Zeitschriftenaufsatz

VL - 63

SP - 330

EP - 338

JO - MAGN RESON MED

JF - MAGN RESON MED

SN - 0740-3194

IS - 2

M1 - 2

ER -