Endoprothetik der akuten Radiuskopffraktur

Standard

Endoprothetik der akuten Radiuskopffraktur. / Burkhart, K J; Wegmann, K; Ries, C; Müller, L P.

In: UNFALLCHIRURG, Vol. 116, No. 8, 08.2013, p. 698-707.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Burkhart, KJ, Wegmann, K, Ries, C & Müller, LP 2013, 'Endoprothetik der akuten Radiuskopffraktur', UNFALLCHIRURG, vol. 116, no. 8, pp. 698-707. https://doi.org/10.1007/s00113-013-2412-3

APA

Burkhart, K. J., Wegmann, K., Ries, C., & Müller, L. P. (2013). Endoprothetik der akuten Radiuskopffraktur. UNFALLCHIRURG, 116(8), 698-707. https://doi.org/10.1007/s00113-013-2412-3

Vancouver

Bibtex

@article{1d4d0ae8cd054e908422a2fb4d0a2a71,
title = "Endoprothetik der akuten Radiuskopffraktur",
abstract = "Radial head arthroplasty is the treatment of choice for non-reconstructble radial head fractures. Solid prostheses made of metal or pyocarbon can restore valgus stability of the elbow independent of design or stem fixation. Short-term and mid-term results show mostly good to excellent results without any evident differences between the different prosthesis philosophies. In order to obtain good results it is important to implant the prosthesis correctly without overfilling and to judge concomitant ligament injuries correctly. This article discusses the anatomical and biomechanical basis of radial head arthroplasty as well as the surgical technique and radiological diagnosis of overfilling.",
keywords = "Arthroplasty/instrumentation, Elbow Joint/injuries, Humans, Joint Prosthesis, Prosthesis Design, Radius Fractures/surgery",
author = "Burkhart, {K J} and K Wegmann and C Ries and M{\"u}ller, {L P}",
year = "2013",
month = aug,
doi = "10.1007/s00113-013-2412-3",
language = "Deutsch",
volume = "116",
pages = "698--707",
journal = "UNFALLCHIRURGIE",
issn = "0177-5537",
publisher = "Springer",
number = "8",

}

RIS

TY - JOUR

T1 - Endoprothetik der akuten Radiuskopffraktur

AU - Burkhart, K J

AU - Wegmann, K

AU - Ries, C

AU - Müller, L P

PY - 2013/8

Y1 - 2013/8

N2 - Radial head arthroplasty is the treatment of choice for non-reconstructble radial head fractures. Solid prostheses made of metal or pyocarbon can restore valgus stability of the elbow independent of design or stem fixation. Short-term and mid-term results show mostly good to excellent results without any evident differences between the different prosthesis philosophies. In order to obtain good results it is important to implant the prosthesis correctly without overfilling and to judge concomitant ligament injuries correctly. This article discusses the anatomical and biomechanical basis of radial head arthroplasty as well as the surgical technique and radiological diagnosis of overfilling.

AB - Radial head arthroplasty is the treatment of choice for non-reconstructble radial head fractures. Solid prostheses made of metal or pyocarbon can restore valgus stability of the elbow independent of design or stem fixation. Short-term and mid-term results show mostly good to excellent results without any evident differences between the different prosthesis philosophies. In order to obtain good results it is important to implant the prosthesis correctly without overfilling and to judge concomitant ligament injuries correctly. This article discusses the anatomical and biomechanical basis of radial head arthroplasty as well as the surgical technique and radiological diagnosis of overfilling.

KW - Arthroplasty/instrumentation

KW - Elbow Joint/injuries

KW - Humans

KW - Joint Prosthesis

KW - Prosthesis Design

KW - Radius Fractures/surgery

U2 - 10.1007/s00113-013-2412-3

DO - 10.1007/s00113-013-2412-3

M3 - SCORING: Zeitschriftenaufsatz

C2 - 23934532

VL - 116

SP - 698

EP - 707

JO - UNFALLCHIRURGIE

JF - UNFALLCHIRURGIE

SN - 0177-5537

IS - 8

ER -